ChromaCL
Live
Colour Cathodoluminescence Imaging in the Scanning
Electron Microscope
ChromaCL™ is an unique product offering live colour cathodoluminescence
(CL) imaging in the SEM. ChromaCL™ operates using the principles
of efficient light collection from the specimen, dispersion onto an array
detector, and live colour mixing of the channels which are measured simultaneously.
For specimens which luminesce at various wavelengths, ChromaCL™
provides a powerful imaging technique. The single scan colour image acquisition
opens new doors to CL studies on geological specimens, beam sensitive
materials and even biological applications, traditionally reliant on optical
techniques.
ChromaCL™ uses DigiScan™, Gatan's powerful 2nd generation
Digital Beam Control system for control of the scan and signal inputs.
ChromaCL™ is suitable for most SEMs and Microprobes with suitable
port access, external scan control, and sufficient beam current to stimulate
colourful CL in the specimen.
|

Quartz image using ChromaCL (above) - with the same
sample viewed as an SE image below

|
| Download
To download a PDF of the ChromaCL
literature click here
|
|
| ChromaCL™ is designed
and manufactured with both user friendliness
and flexibility in mind. Once the mirror
is inserted to a set position, and the
specimen is at the correct working distance,
a single mouse click of the DigiScan™
search, preview, or record button is all
that is needed to acquire a colour CL
with an SE image.
For advanced users alternative dispersion,
channel grouping and software mixing can
be configured and applied to enhance the
versatility of the technique and provide
false colour imaging ideal for specific
specimens. |
 |
|
| |
Software |
ChromaCL™ software allows the user
to specify alternative signal inputs to colour
mixing channels. In this way the software is
flexible and the colour features are not limited
to CL pulse maps. Colour channels can be ascribed
to other suitable analogue or pulse inputs.
|
 |
| |
|
|
|
| |
Specifications |
ChromaCL
Diamond turned parabolic mirror plus light guide.
Magnification imaging from approx. x100 to resolution of technique.
Interface flange to microscope.
70mm retraction of mirror and light guide from set insertion position,
with precision control of X,Y,Z, position.
Spectral transmission 300-800nm.
Adjustable, lockable tilt of dispersion grating.
Multi-alkali, multi-array PMT detector, dynode chain and HT supply, amplification
and pulse discrimination electronics.
DigiScanII™, Digital Beam control platform. Configured to EM model
with cabling. Includes 4 x TTL pulse detection inputs and high bit analogue
input.
DigitalMicrograph™ software containing DigiScan™ and ChromaCL™
plug-ins.
Current specification PC with Firewire input., TFT screen and CDW
ChromaCL SP. Spectroscopy Option.
Integral fixed dipersion mini spectometer.
3648 element array
USB2 interface.
DigitalMicrograph plug-in allows control of acquisition, binning, integration
and dark referencing.
Spectral response 300-850nm.
7.5nm spectral resolution.
|
| |

|
|
 |
© Gatan, Inc. 2007. All rights reserved. |