DigiScan II™ - Definitive
Performance, Digital Beam Control & Image
Processing |
| |
| Quick Digiscan Links Alto,
hot stage,
Cathodoluminescence,
SmartEbic.
XiCLone, ChromaCL |
| |
| DigiScan II™ is Gatan’s
2nd generation digital beam control and image
processing system designed especially for providing
photographic quality digital images, as well
as enhancing advanced scanning electron beam
applications.
DigiScan II works in Gatan’s industry
leading DigitalMicrograph™ software environment
and provides the backbone of advanced EM techniques
from Gatan.
DigiScan II's impressive specifications can
extend the performance of all SEMs. With greater
flexibility of image acquisition and signal
to noise differentiation, DigiScan II can transform
an older analogue microscope, even exceed the
performance of modern SEM framestores.

With DigiScan II, high pixel density images
can be acquired. Poster sized images can provide
higher spatial resolution at lower SEM magnification.
Interesting areas can be “zoomed”
into as a post processing step without introducing
pixellation.
Flexible pixel density and dwell times, high
bit depth acquisition and simultaneous acquisition
of multiple inputs are key to obtaining quality
micro-analytical results. DigiScan II is included
in MonoCL3+, ChromaCL, Spectrum Imaging and
SmartEBIC products, and optional on other CL,
cryo-transfer, hot stages and mechanical testing
products.
|
| Scan control
Configured for microscope’s own
external scan control input. One 3rd party beam
control system can additionally be routed through
DigiScan to allow sharing of a single external
scan control input.
|
|
Continuous mode (search or preview) or single shot mode (record). Configurable
persistence and integrate multiple frame modes. Digital zoom function
allows increased magnification without altering SEM magnification. Waveform
monitor, real-time image rotation, beam control. Area and linescan spectrum
imaging functionality for advanced spectroscopic techniques.
|
|
Image options
Up to 4 analogue and 4 pulse inputs simultaneously. Controlled by software
license and cabling.
User choice of pixel image size in X and Y dimensions, up to 8192 wide
x 8192 high, and recorded at 1, 2, or 4 bytes per pixel. Maximum pixel
resolution may depend on microscope and environment.
User choice of pixel dwell time from 400 nsec to 400 msec per pixel.
|
DigitalMicrograph files
viewed as thumbnails
|
 |
 |
Live color ChromaCL images of geological
specimens acquired using DigiScan II
|
 |
© Gatan, Inc. 2007. All rights reserved. |