High resolution image of Au nanoparticles, drift correction on (image 2)

High resolution image of Au nanoparticles, drift correction on (image 2)

Image of gold (Au) nanoparticles shows how OneView minimizes the impact of sample motion when drift correction is turned on. See High-resolution image of Au nanoparticles, drift correction on (image 1) in the OneView media library to see motion of the original sample when drift correction is turned off.

TEM magnification: 255kx; electron energy: 200 keV; exposure time: 2.56 s; drift correction: on

High resolution image of Au nanoparticles, drift correction on (image 3)

High resolution image of Au nanoparticles, drift correction on (image 3)

Image of gold (Au) nanoparticles shows how OneView minimizes the impact of sample motion when drift correction is turned on. See High-resolution image of Au nanoparticles, drift correction on (image 1) in the OneView media library to see motion of the original sample when drift correction is turned off.

TEM magnification: 255kx; electron energy: 200 keV; exposure time: 2.56 s; drift correction: on

[110] CBED pattern of GaN/InGaN

[110] CBED pattern of GaN/InGaN

OneView camera is able to synchronize frames for 4D STEM applications. Image is related to [110] high resolution image of GaN/InGaN image in the OneView media library.

Camera length: 550 mm; electron energy: 200 keV; exposure time: 5 s; pattern is displayed on linear scale

[110] CBED pattern of GaN/InGaN

[110] CBED pattern of GaN/InGaN

OneView camera is able to synchronize frames for 4D STEM applications. Image is related to [110] high resolution image of GaN/InGaN image in the OneView media library.

Camera length: 550 mm; electron energy: 200 keV; exposure time: 5 s; pattern is displayed on logarithm scale

[110] high resolution image of GaN/InGaN

[110] high resolution image of GaN/InGaN

High-resolution lattice structure is clearly imaged using OneView camera. Image is related to Nanobeam diffraction of GaN/InGaN video and [110] CBED pattern of GaN/InGaN images in the OneView media library.

TEM magnification: 530kx; electron energy: 200 keV; exposure time: 0.16 s; drift correction: on

K2 Summit camera and Quantum energy filter highlight the many forms of the MAC array also known as the bacterial death star

K2 Summit camera and Quantum energy filter highlight the many forms of the MAC array also known as the bacterial death star

Metamorphosis-associated contractile (MAC) structures show a surprising variety of uses in bacteria. Shown above is one particular structure which has been identified to be used in bacterial warfare. Data was collected using a GIF Quantum® energy filter with a K2 Summit® camera and is described by Shikuma et. al., in a recent issue of science.
Scale bar: 100 nm

GIF Quantum LS imaging filter

GIF Quantum LS imaging filter
Maximize your resolution and contrast for low dose imaging applications, including cryo-EM and cryo-electron tomography.

Y2Ti2O7 results on PECS II system

Y2Ti2O7 results on PECS II system

A. Secondary electron B. IQ EBSD map C. IPFZ map

TRIP steel results prepared on PECS II system

TRIP steel results prepared on PECS II system
Results courtesy of Dr. Francois Brisset and Yoann Angilella of Electron Microscopy Department, ICMMO, CNRS- University of Paris- Sud. Data acquired with a Zeiss Supra & Sigma HD and EBSD with Hikari XP and OIM from TSL-EDAX.

A. Secondary electron; (B) EBSD image quality map; (C) IPFZ map

Zircaloy 2

Zircaloy 2 prepared with the PECS II instrument
Results courtesy of Department of Materials, University of Oxford. Professor Angus Wilkinson and Dr. Hamidreza Abdolvand. Data acquired on a Zeiss Compact Merlin equipped with a Bruker Quantax EBSD System.

(A) Secondary electron image of the surface of highly stressed Zircaloy 2 alloy showing twin boundaries; (B) BSED Kikuchi pattern of sample; (C) EBSD Euler angle map; (D) IPFZ map, FOV 1 mm x 0.7 mm